INTRODUCTION: In an analysis of videos recorded in a RCT comparing water exchange (WE) and air insufflation using computer-aided detection (CADe) algorithm, we showed that the strengths of CADe and WE complemented the weaknesses of each other (GIE. 2022;95:1198)…